OCR Text |
Show Fire Department Notice : The following policies and procedures will make it' easier' and more efficient for developers to bring their projects before the Park City Fire Protection District for input relative to fire ; protection and approval by the District. . ' How to Present Projects , I. Developers or their representatives must write to the PCFPD requesting to be included on the agenda of a regularly scheduled meeting or phone Chairman' Robert Burns, Jr. at 649-9325 or 972-5137. Requests for inclusion on the agenda must be received not later than 8:00pm Friday prior to the meeting ;date. Cancellations must be received no later than J.OOOam Monday prior to the meeting date. ' 2. Regularly scheduled meetings fall on the First and third Wednesday of each month. Projects will be reviewed only on these dates. The meetings are held at the Park City fire station ftPaAvfcM ' ':Q3. Jriommission "requires that the developer or his ipintaVQ.l)ertprescnt,',when presenting a project for .;approlfag- ,, ' , . 1 ' P' ih' 1Sfi8feof p,at?s are squired td be submitted for 'approval with the following distribution aftf presentation: j2-a. One copy is to be sent to' the applicable planning ; commission, t. ' - ' "'x " ': One copy is to be retained by the PCFPD. ; ' ! jy tl ci'One copy is to be returned to the developer.4 -j -. The following. will be required to be submitted with each "project if applicable: r . -. '- a. A site;plan showing location of all water mains, fire - hydrants', artd buildings or other structures. ; b. A preliminary floor plan with as much detail as possible, c. An elevation plan snowing ground levels v, ith relation to anv structures. , ' d. An outline of basic structures and building materials.-' . (this.-mav be either a section or narrative.) f " , " j. Items td be? Reviewed for Approval . ... 1 The following is a'.Ust of items that will be;review0d'bv the Commission ""priofcf to gratithjg approval. This lisj will enables t the -developers to !be prepared to discuss the. various-are o " concern arid will greatly speed up the appfpvarprQc'ess: ' 1. Fire hydrant location and spacing. V V;V"' . 2. .Water .mains serving the oroiect with size of lines mdicated. - ... 3. Sources of water to serve the project. 4. Access roads, road grades and turn-around radius on any cul-de-sac. . -1 5. Ijdcatton ofanvf proposed structures on the sites' ' v ' v o- type of construction and materiajs to be utilized on any-structure; any-structure; t -. ,'; ' . "' ' T. PurposeW the u'se'of anv proposed structures., ' "v ' f 8. Acee'ss to voofs and balconies of all structures in excess ,of i. thin v feet in height.. . , h ", ,w .9, Major means'ofgress of any structure. 1 0. Overall height of buildings and structures. , ri ...11; aftic. Resign . ofbndings and structures with regard to basic fire safetv. r ' '. - . - J - -12, Fire protection devices, such as smoked detectors, sprinkler sysiems. wet or dry standpipes, fire extinguishers, , y 13.- Landscaping ronsidratjons such as natural vegetation, vV,.prirhsed tree locationsetc. e: . . 14. f otaliiiipjicKpf the project on thfe Fire District's ability to, adequately protect -fhVproject. . 1 5t Other (as deemed neoessarv at. time presented). - . - ' ' . ' . , . !- . n v::-,v |